|
||||||||||
| PREV CLASS NEXT CLASS | FRAMES NO FRAMES | |||||||||
| SUMMARY: NESTED | FIELD | CONSTR | METHOD | DETAIL: FIELD | CONSTR | METHOD | |||||||||
java.lang.Objectorg.knime.core.node.NodeModel
org.knime.base.node.util.createtempdir.CreateTempDirectoryNodeModel
final class CreateTempDirectoryNodeModel
| Constructor Summary | |
|---|---|
CreateTempDirectoryNodeModel()
|
|
| Method Summary | |
|---|---|
protected DataTableSpec[] |
configure(DataTableSpec[] inSpecs)
This function is called whenever the derived model should re-configure its output DataTableSpecs. |
protected PortObjectSpec[] |
configure(PortObjectSpec[] inSpecs)
Configure method for general port types. |
protected PortObject[] |
execute(PortObject[] inObjects,
ExecutionContext exec)
Execute method for general port types. |
protected void |
loadInternals(File nodeInternDir,
ExecutionMonitor exec)
Load internals into the derived NodeModel. |
protected void |
loadValidatedSettingsFrom(NodeSettingsRO settings)
Sets new settings from the passed object in the model. |
protected void |
onDispose()
Called by the framework when the node is disposed, for instance if the workflow is closed or the node is deleted by the user. |
protected void |
reset()
Override this function in the derived model and reset your NodeModel. |
protected void |
saveInternals(File nodeInternDir,
ExecutionMonitor exec)
Save internals of the derived NodeModel. |
protected void |
saveSettingsTo(NodeSettingsWO settings)
Adds to the given NodeSettings the model specific
settings. |
protected void |
validateSettings(NodeSettingsRO settings)
Validates the settings in the passed NodeSettings object. |
| Methods inherited from class java.lang.Object |
|---|
clone, equals, finalize, getClass, hashCode, notify, notifyAll, toString, wait, wait, wait |
| Constructor Detail |
|---|
CreateTempDirectoryNodeModel()
| Method Detail |
|---|
protected PortObjectSpec[] configure(PortObjectSpec[] inSpecs)
throws InvalidSettingsException
PortObjectSpecs that are defined through the
PortTypes given in the
constructor.
Similarly, the returned output specs need to comply with their port types
spec class (otherwise an error is reported by the framework). They may
also be null.
For a general description of the configure method refer to the
description of the specialized NodeModel.configure(DataTableSpec[])
methods as it addresses more use cases.
configure in class NodeModelinSpecs - The input data table specs. Items of the array could be
null if no spec is available from the corresponding input port
(i.e. not connected or upstream node does not produce an
output spec). If a port is of type
BufferedDataTable.TYPE and no spec is available the
framework will replace null by an empty DataTableSpec
(no columns) unless the port is marked as optional.
InvalidSettingsException - If this node can't be configured.
protected PortObject[] execute(PortObject[] inObjects,
ExecutionContext exec)
throws Exception
PortObject classes that are defined through the
PortTypes given in the
constructor.
Similarly, the returned output objects need to comply with their port
types object class (otherwise an error is reported by the framework).
For a general description of the execute method refer to the description
of the specialized
NodeModel.execute(BufferedDataTable[], ExecutionContext) methods as it
addresses more use cases.
execute in class NodeModelinObjects - The input objects.exec - For BufferedDataTable creation and progress.
Exception - If the node execution fails for any reason.
protected DataTableSpec[] configure(DataTableSpec[] inSpecs)
throws InvalidSettingsException
The passed DataTableSpec elements are never null but can
be empty. The model may return null data table spec(s) for
the outputs. But still, the model may be in an executable state. Note,
after the model has been executed this function will not be called
anymore, as the output DataTableSpecs are then being pulled from the
output DataTables. A derived NodeModel that cannot provide
any DataTableSpecs at its outputs before execution (because the table
structure is unknown at this point) can return an array
containing just null elements.
Implementation note: This method is called from the
NodeModel.configure(PortObjectSpec[]) method unless that method is
overwritten.
configure in class NodeModelinSpecs - The input data table specs (as many as this model has
inputs). Do NOT modify the contents of this array. If no spec
is available for any given port (because the port is not
connected or the previous node does not produce a spec) the
framework will pass an empty DataTableSpec (no
columns) unless the port is marked as optional (in which case the array
element is null).
null DataTableSpec elements are changed to empty
once.
InvalidSettingsException - if the #configure()
failed, that is, the settings are inconsistent with given
DataTableSpec elements.protected void onDispose()
onDispose in class NodeModelprotected void reset()
NodeModel. All components should unregister themselves
from any observables (at least from the hilite handler right now). All
internally stored data structures should be released. User settings
should not be deleted/reset though.
reset in class NodeModel
protected void validateSettings(NodeSettingsRO settings)
throws InvalidSettingsException
NodeSettings object.
The specified settings should be checked for completeness and
consistency. It must be possible to load a settings object validated
here without any exception in the
#loadValidatedSettings(NodeSettings) method. The method
must not change the current settings in the model - it is supposed to
just check them. If some settings are missing, invalid, inconsistent, or
just not right throw an exception with a message useful to the user.
validateSettings in class NodeModelsettings - The settings to validate.
InvalidSettingsException - If the validation of the settings
failed.NodeModel.saveSettingsTo(NodeSettingsWO),
NodeModel.loadValidatedSettingsFrom(NodeSettingsRO)
protected void loadValidatedSettingsFrom(NodeSettingsRO settings)
throws InvalidSettingsException
#validateSettings(NodeSettings) method. The model must set
its internal configuration according to the settings object passed.
loadValidatedSettingsFrom in class NodeModelsettings - The settings to read.
InvalidSettingsException - If a property is not available.NodeModel.saveSettingsTo(NodeSettingsWO),
NodeModel.validateSettings(NodeSettingsRO)protected void saveSettingsTo(NodeSettingsWO settings)
NodeSettings the model specific
settings. The settings don't need to be complete or consistent. If, right
after startup, no valid settings are available this method can write
either nothing or invalid settings.
Method is called by the Node if the current settings need
to be saved or transfered to the node's dialog.
saveSettingsTo in class NodeModelsettings - The object to write settings into.NodeModel.loadValidatedSettingsFrom(NodeSettingsRO),
NodeModel.validateSettings(NodeSettingsRO)
protected void loadInternals(File nodeInternDir,
ExecutionMonitor exec)
throws IOException,
CanceledExecutionException
NodeModel. This method is
only called if the Node was executed. Read all your
internal structures from the given file directory to create your internal
data structure which is necessary to provide all node functionalities
after the workflow is loaded, e.g. view content and/or hilite mapping.
loadInternals in class NodeModelnodeInternDir - The directory to read from.exec - Used to report progress and to cancel the load process.
IOException - If an error occurs during reading from this dir.
CanceledExecutionException - If the loading has been canceled.NodeModel.saveInternals(File,ExecutionMonitor)
protected void saveInternals(File nodeInternDir,
ExecutionMonitor exec)
throws IOException,
CanceledExecutionException
NodeModel. This method is
only called if the Node is executed. Write all your
internal structures into the given file directory which are necessary to
recreate this model when the workflow is loaded, e.g. view content and/or
hilite mapping.
saveInternals in class NodeModelnodeInternDir - The directory to write into.exec - Used to report progress and to cancel the save process.
IOException - If an error occurs during writing to this dir.
CanceledExecutionException - If the saving has been canceled.NodeModel.loadInternals(File,ExecutionMonitor)
|
||||||||||
| PREV CLASS NEXT CLASS | FRAMES NO FRAMES | |||||||||
| SUMMARY: NESTED | FIELD | CONSTR | METHOD | DETAIL: FIELD | CONSTR | METHOD | |||||||||